Reference Guide

Server
Administrator
Trap ID
Not Applicable
VLT0219
Message The arg1 voltage is less than the lower critical threshold.
Arguments
arg1 = name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple
voltage exceptions occur consecutively the system may power down in failsafe
mode.
Recommended
Response
Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum
configuration, inspect and re-install system cables. 3) If the problem persists,
contact technical support. Refer to the product documentation to choose a
convenient contact method.
Category System Health
Subcategory VLT = Voltage
Severity Severity 1 (Critical)
Trap/EventID 2169
LCD Message The <name> voltage is outside of range. Contact support
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
VLT0220
Message The arg1 voltage is greater than the upper warning threshold.
Arguments
arg1 = name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple
voltage exceptions occur consecutively the system may power down in failsafe
mode.
Recommended
Response
Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum
configuration, inspect and re-install system cables. 3) If the problem persists,
contact technical support. Refer to the product documentation to choose a
convenient contact method.
2246