Reference Guide
Server
Administrator
Trap ID
Not Applicable
VLT0205
Message The system board arg1 voltage is within range.
Arguments
• arg1 = name
Detailed
Description
None
Recommended
Response
Action
No response action is required.
Category System Health
Subcategory VLT = Voltage
Severity Severity 3 (Informational)
Trap/EventID 2171
LCD Message No LCD message display defined.
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
VLT0206
Message The memory module arg1 arg2 voltage is less than the lower warning threshold.
Arguments
• arg1 = number
• arg2 = name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple
voltage exceptions occur consecutively the system may power down in failsafe
mode.
Recommended
Response
Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module.
3) If the problem persists, contact technical support. Refer to the product
documentation to choose a convenient contact method.
Category System Health
2237