Reference Guide

70
VLT Event Messages
VLT0100
Message Processor module arg1 voltage is less than the lower warning threshold.
Arguments
arg1 = name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple
voltage exceptions occur consecutively the system may power down in failsafe
mode.
Recommended
Response
Action
1) Review system logs for power supply exceptions. 2) Remove the processor
module. Inspect processor socket for bent pins. 3) If the problem persists, contact
technical support. Refer to the product documentation to choose a convenient
contact method.
Category System Health
Subcategory VLT = Voltage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
VLT0101
Message Processor module arg1 voltage is less than the lower critical threshold.
Arguments
arg1 = name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple
voltage exceptions occur consecutively the system may power down in failsafe
mode.
2230