Reference Guide

Recommended
Response
Action
Remove input power to the system, reseat the DIMM module and restart the
system. If the correctable error persists, then replace the faulty memory module
identified in the message.
Category System Health
Subcategory UEFI = UEFI Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
UEFI0107
Message One or more memory errors have occurred on memory slot: arg1 .
Arguments
arg1 = slot
Detailed
Description
One or more memory errors have occurred on the memory slot identified in the
message. The error occurred during DQS initialization.
Recommended
Response
Action
Remove input power to the system, reseat the DIMM module and restart the
system. If the issues persist, then replace the faulty memory module identified in
the message.
Category System Health
Subcategory UEFI = UEFI Event
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
2073