Reference Guide

UEFI0068
Message The mezzanine card configuration used is not supported on this Chassis.
Detailed
Description
The mezzanine card configuration used is not supported on this Chassis. Server
modules used in different Chassis may require cards with different configuration
properties. For more information, contact your service provider.
Recommended
Response
Action
Make sure that a supported mezzanine card is used and retry the operation. For
more information, see the platform Owners Manual of the Chassis available at the
support site.
Category Configuration
Subcategory UEFI = UEFI Event
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
UEFI0069
Message A CMOS checksum error has occurred. CMOS is reinitialized.
Detailed
Description
A CMOS checksum error has occurred resulting in an invalid BIOS configuration.
BIOS configuraiton is reset to detault settings.
Recommended
Response
Action
Go to the System Setup and configure the desired settings. Save and exit to apply
the settings.
Category System Health
Subcategory UEFI = UEFI Event
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
2051