Reference Guide
UEFI0037
Message Unable to communicate with iDRAC because of an issue in the iDRAC Shared
Memory Architecture (SMA) Intelligent Platform Management Interface (IPMI).
Detailed
Description
Unable to communicate with iDRAC because of an issue in the iDRAC Shared
Memory Architecture (SMA) Intelligent Platform Management Interface (IPMI).
Continuing to boot may result in unexpected power loss because of unknown
power inventory and unavailability of features such as active power management,
thermal management.
Recommended
Response
Action
Do one of the following: 1) Remove input power from the system, wait for 30
seconds, and re-apply input power. Turn on the system. 2) Update the iDRAC
firmware on the system.
Category System Health
Subcategory UEFI = UEFI Event
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
UEFI0038
Message Unable to communicate with iDRAC because of missing interrupts on the Shared
Memory Architecture (SMA) interface.
Detailed
Description
Unable to communicate with iDRAC because an expected interrupt(s) from the
iDRAC SMA (Shared Memory Architecture) interface did not happen. Continuing to
boot may result in unexpected power loss because of unknown power inventory
and unavailability of features such as active power management, thermal
management.
Recommended
Response
Action
Do one of the following: 1) Remove input power from the system, wait for 30
seconds, and re-apply input power. Turn on the system. 2) Update the iDRAC
firmware on the system.
Category System Health
Subcategory UEFI = UEFI Event
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
2034