Reference Guide

Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
UEFI0030
Message A keyboard device is not connected to the system.
Detailed
Description
A keyboard device is not connected to the system.
Recommended
Response
Action
Connect a keyboard device to the system.
Category Configuration
Subcategory UEFI = UEFI Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
UEFI0031
Message PCIe downtrain is detected on arg1 . Expected link width: arg2 Actual link width:
arg3
Arguments
arg1 = device location
arg2 = size
arg3 = size
Detailed
Description
The PCIe device identified in the message was not trained at the expected link
width.
Recommended
Response
Action
Do one of the following: 1) Remove input power from the system, wait for 30
seconds, and re-apply input power. Turn on the system. 2) Update the firmware on
the PCIe device.
2030