Reference Guide

arg2 = temperature
Detailed
Description
The temperature sensor identified in the message is faulty, or the temperature
exceeds the critical threshold. This condition can cause system performance issues
and degradation in the moitoring capability of the system.
Recommended
Response
Action
Review system power policy, check system logs for temperature related failures.
Category System Health
Subcategory TMP = Temperature
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default SNMP Alert;OS Log;None
Server
Administrator
Event ID
5054
Server
Administrator
Trap ID
5054
TMP505
Message The arg1 sensor has failed with a value of arg2 degrees Celsius.
Arguments
arg1 = sensor name
arg2 = temperature
Detailed
Description
The temperature sensor identified in the message has failed.
Recommended
Response
Action
Verify the Embedded System Management (ESM) Log for any sensor related faults.
If there is a failed sensor, replace the system board. For more information, contact
your service provider.
Category System Health
Subcategory TMP = Temperature
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default SNMP Alert;OS Log;None
Server
Administrator
Event ID
5055
2004