Reference Guide

LCD Message No LCD message display defined.
Initial Default SNMP Alert;OS Log;None
Server
Administrator
Event ID
5052
Server
Administrator
Trap ID
5052
TMP503
Message The arg1 sensor state has changed to a warning state with a value of arg2 degrees
Celsius.
Arguments
arg1 = sensor name
arg2 = temperature
Detailed
Description
The temperature sensor identified in the message is faulty, or the temperature
exceeds the warning threshold. This condition can cause system performance
issues and degradation in the moitoring capability of the system.
Recommended
Response
Action
Verify the Embedded System Management (ESM) Log for any sensor related faults.
If there is a failed sensor, replace the system board. For more information, contact
your service provider. Otherwise, change the warning threshold for the
temperature sensor (if applicable) such that it corresponds to the hardware
configuration.
Category System Health
Subcategory TMP = Temperature
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default SNMP Alert;OS Log;None
Server
Administrator
Event ID
5053
Server
Administrator
Trap ID
5053
TMP504
Message The arg1 sensor has detected an error with a value of arg2 degrees Celsius.
Arguments
arg1 = sensor name
2003