Reference Guide
BAT0014
Message The storage battery for disk drive bay arg1 is absent.
Arguments
• arg1 = bay
Detailed
Description
The PERC RAID controller battery may report absent due to disconnect or thermal
exceptions.
Recommended
Response
Action
1) Verify the PERC RAID controller battery installation for the associated bay. 2) If
installed, reseat or reconnect the battery and cables. 3) Check the system logs for
thermal related issues.
Category System Health
Subcategory BAT = Battery Event
Severity Severity 1 (Critical)
Trap/EventID 2225
LCD Message Battery for disk drive bay <bay> is absent. Check battery.
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
BAT0015
Message The arg1 battery is low.
Arguments
• arg1 = name
Detailed
Description
System settings may be preserved if input power is not removed from the power
supplies.
Recommended
Response
Action
Check the battery at the next service window.
Category System Health
Subcategory BAT = Battery Event
Severity Severity 2 (Warning)
Trap/EventID 2226
200