Reference Guide

Server
Administrator
Trap ID
Not Applicable
TMP0133
Message The control panel temperature is greater than the upper critical threshold.
Detailed
Description
Ambient air temperature is too warm or one or more fans may have failed.
Recommended
Response
Action
Check system operating environment and review event log for fan failures.
Category System Health
Subcategory TMP = Temperature
Severity Severity 1 (Critical)
Trap/EventID 2161
LCD Message No LCD message display defined.
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
TMP0134
Message The control panel temperature is outside of range.
Detailed
Description
Ambient air temperature is too warm or cool.
Recommended
Response
Action
Check system operating environment and review event log for fan failures.
Category System Health
Subcategory TMP = Temperature
Severity Severity 1 (Critical)
Trap/EventID 2161
LCD Message No LCD message display defined.
Initial Default IPMI Alert;LC Log
1989