Reference Guide

Server
Administrator
Trap ID
Not Applicable
BAT0009
Message The storage battery is absent.
Detailed
Description
The PERC RAID controller battery may report absent due to disconnect or thermal
exceptions.
Recommended
Response
Action
1) Verify the PERC RAID controller battery installation. 2) If installed, reseat or
reconnect the battery and cables. 3) Check the system logs for thermal related
issues.
Category System Health
Subcategory BAT = Battery Event
Severity Severity 1 (Critical)
Trap/EventID 2225
LCD Message Storage battery is absent. Check battery.
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
BAT0010
Message The storage battery for disk drive bay arg1 is low.
Arguments
arg1 = bay
Detailed
Description
The system has to remain powered on to charge the battery.
Recommended
Response
Action
Allow the PERC RAID controller battery for the associated bay to charge. If the
issue persists, contact technical support. Refer to the product documentation to
choose a convenient contact method.
Category System Health
Subcategory BAT = Battery Event
Severity Severity 2 (Warning)
Trap/EventID 2226
197