Reference Guide

Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
SYS182
Message Unable to collect OS and Application Data because another Lifecycle Controller
operation is currently in progress.
Detailed
Description
Collecting OS and Application Data cannot be completed because Lifecycle
Controller is used by another operation.
Recommended
Response
Action
Make sure all other Lifecycle Controller operations are finished and retry the
operation. Using the iDRAC Web UI, select Server > Job Queue, check the job
queue for unfinished jobs and wait for the jobs to finish before retrying the
operation. Also, check whether there are update packages being executed in the
server OS and wait for these operations to finish before retrying the operation. For
remote web services API access, make sure that the GetRemoteServicesAPIStatus
method returns Ready status, and then retry the operation.
Category System Health
Subcategory SYS = System Info
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
SYS183
Message Unable to allocate memory because of insufficient storage space in iDRAC.
Detailed
Description
The memory cannot be allocated because of insufficient storage space in iDRAC.
Recommended
Response
Action
Reset iDRAC and then retry the operation.
Category System Health
1966