Reference Guide
SYS180
Message There was an issue encountered when attempted to export TTY Log data for the
storage controller arg1 .
Arguments
• arg1 = controller name
Detailed
Description
The TTY log data of the storage controller identified in the message cannot be
exported because an issue was encountered while communicating with the
controller.
Recommended
Response
Action
While exporting the TTY log, make sure that the server is not in BIOS POST, and
then retry the operation. If the issue persists, reset iDRAC, and retry the operation.
Category System Health
Subcategory SYS = System Info
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
SYS181
Message Unable to collect OS and Application Data because the OS Collector is not installed
on the iDRAC.
Detailed
Description
The collect OS and Application Data operation cannot be completed because the
OS Collector is not installed on the iDRAC.
Recommended
Response
Action
Install OS Collector on the iDRAC and retry the operation. To install the OS
Collector using the iDRAC Web UI, get the latest OC Collector update package and
then select the Update and Rollback link from the iDRAC Web UI home page and
upload the install package.
Category System Health
Subcategory SYS = System Info
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default LC Log
1965