Reference Guide
Server
Administrator
Trap ID
5007
SYS114
Message The IPMI status for the interface: arg1 , Baseboard Management Controller (BMC):
arg2 , Sensor Data Records (SDR): arg3 , System Event Log (SEL): arg4 .
Arguments
• arg1 = interface
• arg2 = BMC
• arg3 = SDR
• arg4 = SEL
Detailed
Description
IPMI is supported for identified interface, Baseboard Management Controller
(BMC), Sensor Data Records (SDR), and System Event Log (SEL).
Recommended
Response
Action
If any status is not present, power cycle the system, and apply the latest firmware
update packages for Lifecycle Controller and iDRAC.
Category System Health
Subcategory SYS = System Info
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default OS Log;None
Server
Administrator
Event ID
5012
Server
Administrator
Trap ID
Not Applicable
SYS115
Message The power cord sensor is non-functional.
Detailed
Description
The power cord sensor becomes non-functional because of one of the following
reasons: 1) The power cable may not be connected properly or disconnected. 2)
The power cord sensor in the power supply unit has failed. However, the power
supply unit may still function. 3) There is an input power failure.
Recommended
Response
Action
Do of the following to resolve the issue: 1) Reconnect the power cord to the power
supply unit. 2) Replace the power supply unit that has the failed power cord sensor,
with a new power supply unit. 3) Make sure that the input power supply is restored.
Category System Health
1929