Reference Guide
Recommended
Response
Action
Make sure the Collect System Inventory On Restart (CSIOR) Lifecycle Controller
setting is enabled and reboot the system. Retry the operation after CSIOR has
completed. If the problem persists, reset iDRAC by pressing the System ID button
for at least 15 seconds and retry the operation after iDRAC has fully restarted.
Category Configuration
Subcategory SYS = System Info
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
SYS072
Message System configuration XML import operation timed-out.
Detailed
Description
The import of system configuration XML did not complete as the operation took
too long.
Recommended
Response
Action
Delete all jobs, reset iDRAC by pressing the System ID button for at least 15
seconds, and retry the operation.
Category Configuration
Subcategory SYS = System Info
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
SYS073
Message Unable to apply changes that require system reboot because the Lifecycle
Controller State setting is disabled in the configuration XML.
1904