Reference Guide
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
SYS051
Message The system could not be shut down within the specified time.
Detailed
Description
Sometimes, the operating system on the server may not allow a graceful shutdown
or may not complete within the specified graceful shutdown timeout. This error
indicates that the system could not be shutdown within the time specified. The
default timeout value is 5 minutes and the maximum value allowed is 1 hour.
Recommended
Response
Action
Retry the operation with a longer specified graceful shutdown timeout or with the
system shutdown option.
Category Configuration
Subcategory SYS = System Info
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
SYS052
Message Analyzing iDRAC, System, or Lifecycle Controller configuration for changes to be
applied.
Detailed
Description
Configuration changes that do not require a system restart are currently being
applied.
Recommended
Response
Action
No response action is required.
Category Configuration