Reference Guide

58
SWC Event Messages
SW0725
Message iDRAC7 communication failure.
Detailed
Description
iDRAC7 is busy and does not respond to iDRAC7 configuratorIPMI requests.
Recommended
Response
Action
Try AC power cycling the server or upgrade the iDRAC firmware.
Category Configuration
Subcategory SWC = Software Config
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
SWC0001
Message Unable to save the network settings.
Detailed
Description
The network cable may not be connected or an internal error occurred. For more
information about the failure, see Lifecycle Log.
Recommended
Response
Action
Verify the network cable is connected and retry the operation. If the problem
persists: 1) Turn off the system and disconnect the power cord. 2) Wait for five
seconds. 3) Reconnect the power cord, turn on the system, and retry the
operation.
Category Configuration
Subcategory SWC = Software Config
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
1702