Reference Guide
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
BAR076
Message Unable to collect the Configuration database.
Detailed
Description
The collection and export of Lifecycle Controller Configuration Database failed.
Recommended
Response
Action
Enter System Services in USC, and select Exit and Reboot to reset and update the
database. If the error continues repair the Lifecycle Controller, apply the Dell
Update Packages for USC, diagnostics, device firmware and driver pack and retry
the operation.
Category Configuration
Subcategory BAR = Backup/Restore
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
BAR077
Message Unable to collect the Firmware images.
Detailed
Description
The collection and export of host system firmware images was not successful.
Recommended
Response
Action
Apply Dell Update Packages for all devices and software, and try the operation
again. If the error continues, repair the Lifecycle Controller and apply the packages
again, and retry the operation.
Category Configuration
169