Reference Guide

Detailed
Description
The method name identified in the message could not be successfully completed,
because the number of elements entered for VDPropNameArry and
VDPropValueArray is not equal.
Recommended
Response
Action
Enter a valid parameter, and then retry the operation. For more information about a
valid parameter, refer to the SimpleRAIDProfile document available at Dell Tech
Center http://en.community.dell.com/techcenter/extras/m/white_papers/
20263535.aspx
Category Configuration
Subcategory STOR = Storage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
STOR0701
Message Storage objects are unavailable in the current system configuration.
Detailed
Description
There are no RAID controllers, physical disks or virtual disks discovered by
instrumentation that can be configured.
Recommended
Response
Action
Storage objects are unavailable in the current system configuration. Make sure that
the storage devices are installed in the system, and then retry the operation after
the Collect System Inventory On Restart (CSIOR) feature has updated the system
inventory. If the issue persists, contact your service provider.
Category Configuration
Subcategory STOR = Storage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
1628