Reference Guide

STOR0212
Message The arg1 has failed.
Arguments
arg1 = device name
Detailed
Description
The device (physical disk or an enclosure) identified in the message has failed. The
device (physical disk or an enclosure) failure was detected while performing a
rescan. However, physical disk failures are also detected during a check
consistency operation.
Recommended
Response
Action
Replace the identified device. A failed device is inidicated with a red color "X" status
icon. Perform a rescan after replacing the failed device.
Category Storage
Subcategory STOR = Storage
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
2048
Server
Administrator
Trap ID
75400;80400;85400;90400;95400;100400;105400;110400;115400;120400
STOR022
Message The controller is not security capable.
Detailed
Description
The specified controller does not have the capability to secure virtual disks.
Recommended
Response
Action
No response action is required.
Category Configuration
Subcategory STOR = Storage
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
1596