Reference Guide
STOR0202
Message The configuration file (Path: arg1 ) that contains firmware and driver information for
arg2 is not updated or is incorrectly formatted to complete the comparison.
Arguments
• arg1 = file path
• arg2 = controller name
Detailed
Description
Storage Services is unable to determine whether the system has the minimum
required versions of the RAID controller firmware and drivers because a
configuration file is not readable, corrupted, or has missing data.
Recommended
Response
Action
Reinstall Server Administrator and Storage Services.
Category Storage
Subcategory STOR = Storage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
2166
Server
Administrator
Trap ID
75300
STOR0203
Message The current operating system kernel version and the non-RAID SCSI driver version
are older than the minimum required versions.
Detailed
Description
The version of the operating system kernel and the driver do not meet the
minimum requirements. Storage Services may not be able to display or perform
storage management functions until the system meets the minimum requirements.
Recommended
Response
Action
See the Readme file on the installation media for operating system kernel and
driver version requirements. Update the system to meet the minimum
requirements and then reinstall Storage Services.
Category Storage
Subcategory STOR = Storage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
1590