Reference Guide
SSD1006
Message The arg1 has reached arg2 of warranted device wear-out limit.
Arguments
• arg1 = PCIe solid state device name
• arg2 = percent
Detailed
Description
The PCIe solid state device identified in the message is approaching the warranted
wear-out limit.
Recommended
Response
Action
No response action is required.
Category Storage
Subcategory SSD = PCIe SSD
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
2433
Server
Administrator
Trap ID
90100
SSD1007
Message The arg1 has reached or exceeded its warranted wear-out limit.
Arguments
• arg1 = PCIe solid state device name
Detailed
Description
The PCIe solid state device identified in the message has either reached or
exceeded the warranted wear-out limit.
Recommended
Response
Action
Back up the data on the device, and contact your service provider for further
instructions.
Category Storage
Subcategory SSD = PCIe SSD
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
1572