Reference Guide

Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
RED086
Message Unable to update the Chassis firmware, Chassis Management at Server is not set to
Monitor and Configure.
Detailed
Description
The Chassis firmware cannot be updated because the Chassis Management at
Server (CMAS) attribute is incorrectly set. The CMAS attribute must be set to
Monitor and Configure on the CMC in order to update CMC firmware from and
iDRAC.
Recommended
Response
Action
Make sure that the Chassis Management at Server attribute is set to Monitor and
Configure, and then retry the operation. To set the correct attribute using Chassis
Management Controller (CMC) GUI, navigate to Chassis Overview, then Setup, then
General, and then click on the Chassis management at Server attribute to select the
correct value.
Category Updates
Subcategory RED = FW Download
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
RED087
Message Unable to update the Chassis firmware, Allow CMC Updates Through OS and
Lifecycle Controller is set to Disabled.
Detailed
Description
Unable to update the Chassis firmware because the Allow CMC Updates Through
OS and Lifecycle Controller setting is set to Disabled.
1488