Reference Guide
Recommended
Response
Action
No response action is required.
Category System Health
Subcategory RDU = Redundancy
Severity Severity 3 (Informational)
Trap/EventID 2475
LCD Message No LCD message display defined.
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
5304
Server
Administrator
Trap ID
5304
RDU0012
Message Power supply redundancy is lost.
Detailed
Description
The current power operational mode is non-redundant because of a power supply
exception, a power supply inventory change, or a system power inventory change.
The system was previously operating in a power redundant mode.
Recommended
Response
Action
Check the event log for power supply failures. Review system configuration and
power consumption.
Category System Health
Subcategory RDU = Redundancy
Severity Severity 1 (Critical)
Trap/EventID 2473
LCD Message Lost PSU redundancy. Check PSU cables
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
5306
Server
Administrator
Trap ID
5306
1435