Reference Guide

Detailed
Description
The configuration XML file cannot be imported from a client location when using
Firmware RACADM.
Recommended
Response
Action
When using Firmware RACADM, make sure to import the configuration XML file
from a remote share only.
Category Configuration
Subcategory RAC = RAC Event
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
RAC969
Message Incorrect value specified for the shutdown option.
Detailed
Description
The import operation cannot continue if the value specified for the shutdown
option (-b) is incorrect. The supported values are "Graceful" and "Forced".
Recommended
Response
Action
Make sure to specify either "Graceful" or "Forced" for the shutdown (-b) option.
Category Configuration
Subcategory RAC = RAC Event
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
1415