Reference Guide

Server
Administrator
Trap ID
Not Applicable
RAC918
Message Unable to get the inlet temperature data.
Detailed
Description
Racadm unable to obtain the inlet temperature data. This happens if there is no
data populated in the temperature tables or if the underlying instrumentation does
not return valid values.
Recommended
Response
Action
Wait for the underlying instrumentation to populate the thermal tables. Retry the
operation.
Category System Health
Subcategory RAC = RAC Event
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
RAC919
Message Copy to remote share unsuccessful. Remote share might be write protected.
Detailed
Description
Racadm could not export the inlet temperature history file to the specified remote
share. This is because the specified share may be write- protected.
Recommended
Response
Action
To export the file, change the permissions on the remote share. Else, create
another share with write permissions.
Category Configuration
Subcategory RAC = RAC Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
1391