Reference Guide
Detailed
Description
The specified value is not within the valid range. To set the LED state to off, enter 0.
To set the LED state to on, enter 1.
Recommended
Response
Action
Set the numeric value to 0 (Off) or 1 (On).
Category Configuration
Subcategory RAC = RAC Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
RAC915
Message Unable to change auto-negotiation property for the NIC.
Detailed
Description
The auto-negotiation property for the iDRAC NIC can be changed only if the NIC is
in dedicated mode. To change the NIC mode to dedicated, an iDRAC Enterprise
license is required.
Recommended
Response
Action
Change the NIC mode to dedicated mode by using "racadm set idrac.nic.selection
<1 | Dedicated>", and retry the operation.
Category Configuration
Subcategory RAC = RAC Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
1389