Reference Guide

Detailed
Description
Unable to set USB group objects because the user account identified in the
message does not have the System Control privilege, which is required for this
operation.
Recommended
Response
Action
Contact the iDRAC system administrator and get the System Control privilege
added to the account identified in the message or use account credentials that
have System Control privilege and retry the operation.
Category Configuration
Subcategory RAC = RAC Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
RAC1161
Message Unable to initiate the techsupreport collect operation for the Tech Support Report
(TSR) because the iDRAC Service Module (iSM) is not running.
Detailed
Description
Unable to initiate the techsupreport collect operation because the iDRAC Service
Module (iSM) is not running.
Recommended
Response
Action
Run the command racadm get iDRAC.ServiceModule to make sure that iDRAC
Service Module is installed and running on the server operation system (OS) and
also to verify that the collection of the server OS data is enabled.
Category Configuration
Subcategory RAC = RAC Event
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
1376