Reference Guide
RAC1134
Message Unable to export the Lifecycle log data, because the export file size larger than
25MB and cannot be processed locally.
Detailed
Description
Unable to export the Lifecycle log data, because the export file size larger than
25MB and cannot be processed locally.
Recommended
Response
Action
Export the Lifiecycle Log to a network file share. Using the RACADM command line
utility, run the lclog export command with --complete option and related network
file share parameters, and then retry the operation. For more information about the
--complete option, run the "racadm help lclog export" command at the command
line interface.
Category Configuration
Subcategory RAC = RAC Event
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
RAC1135
Message Unable to run the RACADM command because an internal instrumentation
component has stopped functioning.
Detailed
Description
The RACADM command could not be run because the internal instrumentation
components are either busy or have stopped functioning.
Recommended
Response
Action
Wait for a minute for the internal instrumentation component to respond, and then
retry the operation. If the issue persists, reset the iDRAC by pressing the System ID
button for 15 seconds, wait for the iDRAC to finish restarting, and then retry the
operation. If the issue continues to persist, contact your service provider.
Category Configuration
Subcategory RAC = RAC Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None