Reference Guide
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
RAC1112
Message Unable to delete the pending values for the specified device because the iDRAC
internal storage is in use by a currently running job.
Detailed
Description
Unable to clear the pending state from the attributes for a RAID object. A job is
currently running and iDRAC internal storage is in use.
Recommended
Response
Action
Retry the operation after any currently running jobs have completed. Jobs can be
monitored by running the racadm command "racadm jobqueue view".
Category Configuration
Subcategory RAC = RAC Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
RAC1113
Message Unable to perform the preview operation because the options -b, -c, -w, and -s
must not be used with the --preview option.
Detailed
Description
The configuration XML preview operation cannot be executed because the -b, -s,
and -w options must not be used with the --preview option.
Recommended
Response
Action
Remove the -b, -w, and -s options wihen using the --preview option and retry the
operation.
Category Configuration
1353