Reference Guide

Recommended
Response
Action
Check the minimum non critical threshold level using an appropriate RACADM
command. For example, to view the minimum non critical threshold value of a
sensor, run the racadm getsensorinfo command at the command line interface,
and then retry the operation. For more information about other RACADM
commands, run the racadm help command.
Category Configuration
Subcategory RAC = RAC Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
RAC1072
Message Unable to set maximum non critical threshold value of arg1 , because the value
entered is less than, or equal to the minimum critical threshold value.
Arguments
arg1 = System Board Inlet Temp
Detailed
Description
The maximum non critical threshold value identified in the message cannot be set,
because the value entered is less than or equal to the minimum critical threshold
value.
Recommended
Response
Action
Check the minimum critical threshold level using an appropriate RACADM
command. For example, to view the minimum critical threshold value of a sensor,
run the racadm getsensorinfo command at the command line interface, and then
retry the operation. For more information about other RACADM commands, run
the racadm help command.
Category Configuration
Subcategory RAC = RAC Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
1350