Reference Guide
Recommended
Response
Action
Check the maximum non critical threshold level using an appropriate RACADM
command. For example, to view the maximum non critical threshold value of a
sensor, run the racadm getsensorinfo command at the command line interface,
and then retry the operation. For more information about other RACADM
commands, run the racadm help command.
Category Configuration
Subcategory RAC = RAC Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
RAC1069
Message Unable to set minimum non critical threshold value of arg1 , because the value
entered is greater than, or equal to the maximum critical threshold value.
Arguments
• arg1 = System Board Inlet Temp
Detailed
Description
The minimum non critical threshold value identified in the message cannot be set,
because the value entered is greater than, or equal to the maximum critical
threshold value.
Recommended
Response
Action
Check the maximum critical threshold level using an appropriate RACADM
command. For example, to view the maximum critical threshold value of a sensor,
run the racadm getsensorinfo command at the command line interface, and then
retry the operation. For more information about other RACADM commands, run
the racadm help command.
Category Configuration
Subcategory RAC = RAC Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
1348