Trap ID
Not Applicable
RAC1067
Message Unable to set the minimum non critical threshold value of arg1 , because the value
entered is lesser than, or equal to the minimum critical threshold value.
Arguments
• arg1 = System Board Inlet Temp
Detailed
Description
The minimum non critical threshold value identified in the message cannot be set,
because the value entered is lesser than, or equal to the minimum critical threshold
value.
Recommended
Response
Action
Check the minimum critical threshold level using an appropriate RACADM
command. For example, to view the minimum threshold value of a sensor, run the
racadm getsensorinfo command at the command line interface, and then retry the
operation. For more information about other RACADM commands, run the racadm
help command.
Category Configuration
Subcategory RAC = RAC Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
RAC1068
Message Unable to set minimum non critical threshold value of arg1 , because the value
entered is greater than, or equal to the maximum non critical threshold value.
Arguments
• arg1 = System Board Inlet Temp
Detailed
Description
The minimum non critical threshold value identified in the message cannot be set,
because the value entered is greater than, or equal to the maximum non critical
threshold value.