Reference Guide
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
RAC1017
Message Successfully modified the object value and the change is in pending state.
Detailed
Description
Any staged operation requires a job and system reboot to apply the object values.
Recommended
Response
Action
To apply modified value, create a configuration job and reboot the system. To
create the commit and reboot jobs, use "jobqueue" command. For more
information about the "jobqueue" command, see RACADM help.
Category Configuration
Subcategory RAC = RAC Event
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
RAC1018
Message The specified object or syntax is invalid.
Detailed
Description
This occurs when an incorrect syntax is used or an incorrect object is specified
during the command invocation.
Recommended
Response
Action
Make sure to use the correct syntax and correct object names, and retry the
operation. For information related to the corresponding group, see RACADM help
or the RACADM Users Guide.
Category Configuration
Subcategory RAC = RAC Event