Reference Guide

Server
Administrator
Trap ID
Not Applicable
RAC0712
Message Server failed to power up due to zero power allocated.
Detailed
Description
Server failed to power up due to zero power allocated.
Recommended
Response
Action
Utilize the Chassis Management Controller web interface to check available power
and server power requirements. If sufficient power is available, allocate power
necessary and retry the operation.
Category Audit
Subcategory RAC = RAC Event
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
RAC0713
Message Server failed to power up due to fabric mismatch.
Detailed
Description
Server failed to power up due to fabric mismatched.
Recommended
Response
Action
Ensure that the hardware comtibility between the IO Module (IOM) and the
Mezzanine (Mezz) card is correct. Check the M1000e Hardware Manual for correct
component compatibility.
Category Audit
Subcategory RAC = RAC Event
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default LC Log
1295