Reference Guide
Detailed
Description
Physical disks cannot be displayed. This error may occur if the host system is
powered off, physical disks are removed, or incorrect filters are applied.
Recommended
Response
Action
1. Check if the host system is powered off or shutdown. 2. Check if the physical
disks are inserted into the enclosure or attached to the backplane. 3. Check if
correct filters are applied. 4. Check that the Storage Enclosure is on. 5. verify that
the adapter cables are properly connected and there are no bent pins.
Category Storage
Subcategory RAC = RAC Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
RAC0512
Message There are no virtual disks to be displayed.
Detailed
Description
Virtual disks cannot be displayed. This error may occur if the host system is
powered off, no virtual disks were created, or incorrect filters are applied.
Recommended
Response
Action
1. Check if the host system is ON. 2. Check if virtual disks are created. 3. Check if
correct filters are applied. 4. Check if the Storage Enclosure is ON. 5. Verify that the
adapter cables are properly connected and there are no bent pins.
Category Storage
Subcategory RAC = RAC Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
1259