Reference Guide

Detailed
Description
The system is communicating to the baseboard management controller (BMC).
Recommended
Response
Action
No response action is required.
Category System Health
Subcategory ASR = Auto Sys Reset
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
ASR0100
Message The BIOS watchdog timer reset the system.
Detailed
Description
The operating system or an application failed to communicate to the system board
within the timeout period. The system was reset per the configured setting. (IPMI
sensor type code 23h offset 01h event 3:0 - 2h)
Recommended
Response
Action
Check the operating system, application, hardware, and system event log for
exception events.
Category System Health
Subcategory ASR = Auto Sys Reset
Severity Severity 1 (Critical)
Trap/EventID 2233
LCD Message No LCD message display defined.
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
121