Reference Guide

Category System Health
Subcategory ASR = Auto Sys Reset
Severity Severity 1 (Critical)
Trap/EventID 2233
LCD Message No LCD message display defined.
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
ASR0008
Message The watchdog timer interrupt was initiated.
Detailed
Description
The operating system or an application failed to communicate to the baseboard
management controller (BMC) within the timeout period. The BMC invoked a
system interrupt. (IPMI sensor type code 23h - offset 00h)
Recommended
Response
Action
Check the operating system, application, hardware, and system event log for
exception events.
Category System Health
Subcategory ASR = Auto Sys Reset
Severity Severity 1 (Critical)
Trap/EventID 2233
LCD Message No LCD message display defined.
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
ASR0009
Message The system returned from a watchdog timer event.
120