Reference Guide
Server
Administrator
Trap ID
5202
AMP403
Message The arg1 sensor state has changed to a warning state with a value of arg2 A.
Arguments
• arg1 = sensor name
• arg2 = current
Detailed
Description
The current sensor identified in the message is faulty or the current drawn by the
system exceeds the warning threshold. This condition can cause system
performance issues and degradation in the moitoring capability of the system.
Recommended
Response
Action
Verify the Embedded System Management (ESM) Log for any sensor related faults.
If there is a failed sensor, replace the system board. For more information, contact
your service provider. Otherwise, change the warning threshold for the current
sensor such that it corresponds to the hardware configuration.
Category System Health
Subcategory AMP = Amperage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default SNMP Alert;OS Log;None
Server
Administrator
Event ID
5203
Server
Administrator
Trap ID
5203
AMP404
Message The arg1 sensor detected an error with a value of arg2 A.
Arguments
• arg1 = sensor name
• arg2 = current
Detailed
Description
The current sensor identified in the message is faulty or the current drawn by the
system exceed the critical threshold. This condition can cause system performance
issues and degradation in the moitoring capability of the system.
116