Reference Guide

Detailed
Description
The server identified in the message could not be successfully turned on because
of incompatibility between the chassis PCIe components and mezzanine card.
Recommended
Response
Action
Make sure that the chassis PCIe components and mezzanine card are compatible.
For information about compatibility of hardware components, see the Modular
System Chassis Hardware Manual.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 1 (Critical)
Trap/EventID 8417
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8670
Message Unable to turn on server arg1 because the required power arg2 AC Watts exceeds
the subsystem Connector Limit arg3 AC Watts for IO modules, Blowers and
Servers.
Arguments
arg1 = slot ID
arg2 = power level
arg3 = power limit
Detailed
Description
The server identified in the message cannot be turned on if the Connector Limit for
the subsystems identified in the message is exceeded .
Recommended
Response
Action
Make sure the system operates within the subsystem Connector Limit for the
components specified. To review power budget information select Chassis
Overview -> Power -> Budget Status. Turn off unused components within the
subsystem to make power available for the server to turn on or turn off low priority
servers and try the operation again.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID 8418
LCD Message No LCD message display defined.
1156