Reference Guide

Server
Administrator
Trap ID
Not Applicable
PWR8654
Message Chassis Management Controller (CMC) is unable to send power allocation
information to the component arg1 - arg2 .
Arguments
arg1 = component name
arg2 = component id
Detailed
Description
CMC could not successfully send the power allocation information to the
component identified in the message, because either iDRAC is stopped after the
power allocation was sent by CMC or the communication between CMC and
iDRAC has ended.
Recommended
Response
Action
Perform a Virtual Reseat operation of the component, and then retry the operation.
To virtually reseat a component, log in to the CMC Web interface, select Chassis
Overview > Troubleshooting > Reset Components > select the option
corresponding to the component, and then click Virtual Reseat.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8655
Message Chassis Management Controller (CMC) is unable to turn on the component arg1 -
arg2 because of insufficient power. The minimum required power is arg3 AC Watts,
but only arg4 AC Watts is available.
Arguments
arg1 = component name
arg2 = slot number
arg3 = min power
arg4 = available power
1151