Reference Guide

Detailed
Description
The Power buttons for all multinode sleds in the chassis are disabled. This
operation is only applicable to the multinode sleds available, and does not affect
other servers in the chassis.
Recommended
Response
Action
The multinode sled power button is disabled. To enable the chassis power button
use the CMC RACADM command line interface, CMC Web interface. Using the
command line, enter "racadm config -g cfgChassisPower -o
cfgChassisSledPowerButtonEnable 1". Using the Web interface, click Server
Overview > Power > Control. Clear the "Disable power button for all multinode
sleds in the chassis" check box.
Category Configuration
Subcategory PWR = Power Usage
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8602
Message Multinode sled power button enabled
Detailed
Description
The Power buttons for all multinode sleds in the chassis are enabled. This
operation is only applicable to the multinode sleds available, and does not affect
other servers in the chassis.
Recommended
Response
Action
The multinode sled power button is enabled. To disable the chassis power button
use the CMC RACADM command line interface, CMC Web interface. Using the
command line, enter "racadm config -g cfgChassisPower -o
cfgChassisSledPowerButtonEnable 0". Using the Web interface, click Server
Overview > Power > Control. Set the "Disable power button for all multinode sleds
in the chassis" check box.
Category Configuration
Subcategory PWR = Power Usage
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
1150