Reference Guide
PWR8596
Message Chassis Management Controller is unable to turn on server- arg1 because PSU
redundancy is lost and the available power is insufficient.
Arguments
• arg1 = slot number
Detailed
Description
The Chassis Management Controller cannot turn on the server identified in the
message, because PSU redundancy is lost or PSUs are removed. Sufficient power is
not available for the operation.
Recommended
Response
Action
Make sure there is enough power supply to distribute power. Go to, the Chassis
Overview > Power > Power Budget Status. In the Total Input Power Available For
Allocation field, view the available power. To add more power, insert more PSUs or
remove unused components from the chassis. When enough power is available,
retry the operation.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8597
Message The Power Supply Unit (PSU) arg1 is turned off because it is not supported by the
Chassis.
Arguments
• arg1 = PSU number
Detailed
Description
The identified Power Supply Unit (PSU) is turned off because it is not supported by
the Chassis.
Recommended
Response
Action
Replace the PSU identified in the message with an appropriate unit, and then retry
the operation. For a list of PSUs that are compatible, consult the system Owners
Manual or contact your service provider.
Category Audit
Subcategory PWR = Power Usage
1148