Reference Guide

PWR8591
Message Servers are turned off to allocate power to the newly inserted hard disk drives.
Detailed
Description
Before inserting hard disk drives, always make sure the Chassis has enough
available power. Otherwise operating servers may be turned off.
Recommended
Response
Action
Make sure there is enough power supply to distribute power. Go to, the Chassis
Overview > Power > Power Budget Status. In the Total Input Power Available For
Allocation field, view the available power. To add more power, insert more PSUs or
remove unused components from the chassis.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 1 (Critical)
Trap/EventID 8417
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8592
Message Chassis Management Controller is unable to turn on or turn off the chassis because
another chassis power operation is in progress.
Detailed
Description
The request to turn on or turn off the chassis was issued before the previous power
operation was completed.
Recommended
Response
Action
Retry the operation after the current operation is complete.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None