Reference Guide
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8588
Message Chassis Management Controller is unable to turn on server- arg1 because a chassis
infrastructure firmware update is in progress.
Arguments
• arg1 = slot number
Detailed
Description
The server identified in the message cannot be turned on while a chassis
infrastructure firmware update operation is in progress.
Recommended
Response
Action
The chassis infrastructure firmware update is in progress. Retry the operation after
the firmware update is complete.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8589
Message The server- arg1 does not have PCIe Mezzanine card in slot B1.
Arguments
• arg1 = slot number
Detailed
Description
The PCIe Mezzanine card in the slot B1 is absent. Without PCIe Mezzannine cards,
the chassis PCIe cards will not be available for servers.
1143