Reference Guide

Detailed
Description
If power redundancy is lost and the server Performance Over Power Redundancy
feature is disabled, the server turn-on will not be allowed.
Recommended
Response
Action
To enable the server to be turned-on, on the Power Configuration page in the Web
UI, enable the server Performance Over Power Redundancy option . Using the
RACADM utility, run the following command "racadm config -g cfgChassisPower -
o cfgChassisPerformanceOverRedundancy 1". Then retry the operation.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8585
Message Chassis Management Controller granted the power required to turn on server-
arg1 .
Arguments
arg1 = slot number
Detailed
Description
Chassis Management Controller granted the power required to turn on the server
identified in the message.
Recommended
Response
Action
No response action is required.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
1141