Reference Guide

LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8583
Message Chassis Management Controller is unable to turn on server- arg1 because
unacknowledged 110V PSUs are present.
Arguments
arg1 = slot number
Detailed
Description
To enable 110V operation, the Allow 110VAC Operation feature must be enabled. If
the feature is not enabled, the server turn-on operation will not be processed.
Recommended
Response
Action
On the Power Configuration page, in the Web UI, select the Allow 110VAC
Operation for power supplies and retry the operation. Using the RACADM utility,
run the following command, "racadm config -g cfgChassisPower -o
cfgChassisAllow110VACOperation 1".
Category Audit
Subcategory PWR = Power Usage
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8584
Message Chassis Management Controller is unable to turn on server- arg1 because the
power supply redundancy is lost and Performance Over Power Redundancy
feature is disabled and the power required is less than the available power.
Arguments
arg1 = slot number
1140