Reference Guide
Trap/EventID 2179
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
AMP400
Message The arg1 sensor has failed, and the last recorded value by the sensor was arg2 A.
Arguments
• arg1 = sensor name
• arg2 = current
Detailed
Description
The current sensor identified in the message has failed. This condition can cause
system performance issues and degradation in the moitoring capability of the
system.
Recommended
Response
Action
Check the Embedded System Management (ESM) Log for any sensor related faults.
If there is a failed sensor, replace the system board. For more information, contact
your service provider.
Category System Health
Subcategory AMP = Amperage
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default OS Log;None
Server
Administrator
Event ID
5200
Server
Administrator
Trap ID
Not Applicable
AMP401
Message Unable to read the arg1 sensor value.
Arguments
• arg1 = sensor name
114