Reference Guide
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8573
Message The Chassis Management Controller is unable to communicate to the iDRAC,
when trying to turn off the server arg1 .
Arguments
• arg1 = server id
Detailed
Description
The Chassis Management Controller is not able to communicate with the iDRAC
on the server identified in the message. Therefore the server could not be turned
off. This situation may occur when iDRAC is restarting.
Recommended
Response
Action
Wait for three minutes, and then retry the operation. If the issue persists, remove
and reinsert the server and wait for the iDRAC to finish restarting before retying the
operation.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID 8418
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8574
Message The Chassis Management Controller is unable to communicate to the iDRAC,
when trying to hard reset the server arg1 .
Arguments
• arg1 = slot number
Detailed
Description
The Chassis Management Controller is not able to communicate with the iDRAC
on the server identified in the message. Therefore the server could not be hard
reset. This situation may occur when iDRAC is restarting.
1134